SINEE EM730 VFD Parameters setting for Three Wire Control Mode Operation with Start, Stop, Reverse, Speed 1, Speed 2 Command.
F12.14 "Restoration of factory defaults" 1: restoration of factory
F00.01 Drive control mode of motor 1 0: V/F control (VVF)
F00.02 Options of command source 1: terminal control (LOC/REM indicator: OFF)
F00.03 Options of terminal control mode "2: terminal RUN (forward), Xi (stop) and F/R
(reverse)"
F00.14 Acceleration time 1 10S
F00.15 Deceleration time 1 10S
F00.16 Maximum frequency 50
F00.18 Upper frequency limit 50
F00.19 Lower frequency limit 0
F00.20 F00.20 0: consistent direction
F00.21 Reverse control 0: Allow forward/reverse running
F02.00 "Options of X1 digital input function" 1: terminal running (RUN)
F02.01 "Options of X2 digital input function" 3: stop control in three-line operation (NC STOP SWITCH)
F02.02 "Options of X3 digital input function" 2: running direction (F/R)
F02.03 "Options of X4 digital input function" 11: multi-segment speed terminal 1
F02.04 "Options of X5 digital input function" 12: multi-segment speed terminal 2
F08.00 "Multi-segment speed 1" 5
F08.01 "Multi-segment speed 2" 10
F08.02 "Multi-segment speed 3" 15
F08.03 "Multi-segment speed 4" 20